142 research outputs found

    Voltage harmonic reduction for randomly time-varying source characteristics and voltage harmonics

    Get PDF
    This material is posted here with permission of the IEEE. Such permission of the IEEE does not in any way imply IEEE endorsement of any of Brunel University's products or services. Internal or personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution must be obtained from the IEEE by writing to [email protected]. Copyright @ 2006 IEEEPotential applications of probabilistic modeling of current and voltage harmonics concern many aspects of power system engineering as accurate prediction of power system harmonic behavior provides important information to utility companies and equipment designers. In this paper, a method of reducing the expected value of the total voltage harmonic distortion for a specified range of source impedance values at different buses by using LC compensators, where it is desired to maintain a given power factor at a specified value, is presented. The criterion is based on mean value estimation of source and load characteristics, which are enabled by sampling measurements performed on the examined electrical plant as well as statistical analysis

    Capacitive compensation at nonsinsoidal buses based on IEEE Std. 18-1992

    Get PDF
    This material is posted here with permission of the IEEE. Such permission of the IEEE does not in any way imply IEEE endorsement of any of Brunel University's products or services. Internal or personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution must be obtained from the IEEE by writing to [email protected]. Copyright @ 2003 IEEEThis letter presents a proposed method for finding the optimum fixed compensating capacitor to minimize the voltage harmonic distortion at a load bus while holding the power factor at a desired value and constraining the nameplate kiloVAr of the compensating capacitor, its rated voltage RMS, and its rated current RMS as constraints according to IEEE Std. 18-1992. Also, the values of the compensating capacitor, which would create resonant conditions, would be omitted from the solution. Finally, the contribution of the newly developed method is demonstrated in an example taken from previous publications

    The most economical power factor correction according to tariff structures in Egypt

    Get PDF
    This material is posted here with permission of the IEEE. Such permission of the IEEE does not in any way imply IEEE endorsement of any of Brunel University's products or services. Internal or personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution must be obtained from the IEEE by writing to [email protected]. Copyright @ 2005 IEEEA method of applying power-factor (PF) correction capacitors is discussed based on net savings maximization according to Egyptian's Tariff. Test results from examples taken from existing publications are presented. The purpose of this application technique is to utilize existing electrical distribution equipment in the installation of very large values of PF correction capacitors. It is concluded that LC compensators can be installed, thus providing maximum benefits from penalty elimination, system losses reduction, release of system transformer capacity, and minimum switching transients. Paybacks of less than one year can be expected

    Comparison of different optimization criteria for optimal sizing of hybrid active power filters parameters

    Get PDF
    Praise Worthy Prize granted a permission for Brunel University London to archive this article in BURA.Harmonic distortion in power systems has increased considerably due to the increasing use of nonlinear loads in industrial firms and elsewhere. This distortion can give rise to overheating in all sectors of the power system, leading to reduced efficiency, reliability, operational life and sometimes failure. This article seeks to propose a new methodology for the optimal sizing of hybrid active power filter (HPF) parameters in order to overcome the difficulties in hybrid power filters design when estimating the preliminary feasible values of the parameters. Sequential Quadratic Programming based on FORTRAN subroutines is used to find out the planned filter size in two different optimization criteria depending on design concerns. The first criterion is to minimize the total voltage harmonic distortion. The second one is to maximize the load power factor, while taking into account compliance with IEEE standard 519-1992 limits for the total voltage harmonic distortion and the power factor.The effectiveness of the proposed filter is discussed using four exemplary case

    LC compensators based on transmission loss minimization for nonlinear loads

    Get PDF
    This material is posted here with permission of the IEEE. Such permission of the IEEE does not in any way imply IEEE endorsement of any of Brunel University's products or services. Internal or personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution must be obtained from the IEEE by writing to [email protected]. Copyright @ 2004 IEEEThis paper presents a method employing the penalty function search algorithm to determine the LC compensator value for the optimal power factor correction in nonsinusoidal systems. The objective of the proposed method is to minimize the transmission loss while the power factor and efficiency are taken as constraints and utilized in order to solve the multiobjective optimization problem by transforming it into a single objective one. Examples show that the load nonlinearity can have a significant impact on optimal compensator sizes

    Optimal allocation of FACTS devices in distribution networks using Imperialist Competitive Algorithm

    Get PDF
    Copyright © 2005-2015 Praise Worthy Prize. The publisher granted a permission to the author to archive this article in BURA.FACTS devices are used for controlling the voltage, stability, power flow and security of transmission lines. Imperialist Competitive is a recently developed optimization technique, used widely in power systems. This paper presents an approach to finding the optimal location and size of FACTS devices in a distribution network using the Imperialist Competitive technique. IEEE 30-bus system is used as a case study. The results show the advantages of the Imperialist Competitive technique over the conventional approaches. © 2013 Praise Worthy Prize S.r.l. - All rights reserved

    Power quality issues of 3MW direct-driven PMSG wind turbine

    Get PDF
    This paper presents power quality issues of a grid connected wind generation system with a MW-class direct-driven permanent magnet synchronous generator (PMSG). A variable speed wind turbine model was simulated and developed with the simulation tool of PSCAD/EMTDC. The model includes a wind turbine with one mass-model drive train model, a PMSG model and a full-scale voltage source back to back PWM converter. The converter controller model is employed in the dq-synchronous rotating reference frame and applied to both generator and grid sides. To achieve maximum power point tracking, a tip speed ratio method is applied in machine side, whereas DC voltage control is applied in grid side to achieve constant DC voltage. Due to wind fluctuation and power oscillation as a result of wind shear and tower shadow effects (3p), there will be a fluctuation in the output power and voltage. The concerned power quality issues in this work are Harmonics, power fluctuation and flicker emission. The measurements will be carried out under different wind speed and circumstances